秸稈氣好色先生在线观看小故障你學會了也可以輕鬆解決
1、節溫器損壞
1. Thermostat damaged
秸稈氣好色先生在线观看如果出現水溫如過高的現象,一般是由於節溫器失效的緣故,致使冷卻液大循環流速減慢,需要購買新的節溫器進行替換。
If the water temperature of the straw gas generator set is too high, it is generally due to the failure of the thermostat, which slows down the circulation flow rate of the coolant. A new thermostat needs to be purchased for replacement.
2、風扇皮帶開裂的解決方
2. Solution to cracking of fan belt
秸稈氣好色先生在线观看的電扇皮帶損壞,應立即停機進行替換。假如當下沒有條件更行替換,能夠將原電扇皮帶的斷口兩頭鑽兩個小孔,再用粗金屬絲把斷皮帶銜接進來做應急運用。需求留意的是,鑽孔和斷麵間應保存恰當的間隔,防止將孔拉裂,金屬絲的接頭應留在皮帶的外側,皮帶不要調的過緊。假如電扇皮帶損壞較嚴峻無法銜接,能夠把繩子或布帶、牛皮帶用鐵絲紮緊,編製成一根暫時運用的皮帶。格外要留意長短和粗細應與原皮帶持平,繩頭應當夾在綁好。
The fan belt of the straw gas generator set is damaged and should be stopped immediately for replacement. If there are no conditions to replace it at the moment, two small holes can be drilled at both ends of the original fan belt fracture, and thick metal wire can be used to connect the broken belt for emergency use. It should be noted that appropriate spacing should be maintained between drilling and cross-sections to prevent holes from tearing. The joints of the metal wires should be left on the outside of the belt, and the belt should not be adjusted too tightly. If the fan belt is severely damaged and cannot be connected, it is possible to tie the rope, cloth belt, or cowhide belt with iron wire and weave it into a temporary belt for use. Special attention should be paid to the length and thickness of the belt, which should be level with the original belt, and the rope end should be clamped in the center and tied tightly.


3、散熱器水管漏水
3. Radiator water pipe leakage
秸稈氣好色先生在线观看的使用過程中,散熱器水管內部的水溫過高,外部的溫度過低。或是因為秸稈氣秸稈氣好色先生在线观看組的震蕩,很容易造成水箱的水管漏水的現象。秸稈氣秸稈氣好色先生在线观看組的水箱漏水可以把散煙絲放入水箱內,利用水循環的壓力,來使煙絲堵塞在散熱管的漏水處以便暫時運用。假如水箱散熱管漏水狀況較嚴峻,能夠把漏水處剪斷,再把棉花團塗上番筧者在被剪斷的散熱管處,再用鉗子把被剪斷的散熱管的頭部夾扁,再卷邊壓緊即可止住漏水狀況。
During the use of straw gas generator sets, the water temperature inside the radiator water pipe is too high and the external temperature is too low. Or it may be due to the vibration of the straw gas generator set, which can easily cause water leakage in the water tank pipes. The water tank of the straw gas and straw gas generator unit is leaking. The scattered tobacco can be placed into the water tank, and the pressure of the water circulation can be used to block the tobacco at the leakage point of the heat dissipation pipe for temporary use. If the water leakage situation of the radiator heat pipe is severe, you can cut off the leaking area, then apply soap to the cotton ball at the cut heat pipe, use pliers to flatten the head of the cut heat pipe, and then roll the edge tightly to stop the leakage situation.
4、水泵漏水
4. Water pump leakage
秸稈氣好色先生在线观看使用鋁水泵,有時會出現密封不嚴的現象。應當把水封平麵修磨平坦,或者把水封翻轉180°再安裝運用。假如止推橡皮圈損壞、脹大變形、繃簧彈力缺乏、折斷等,都應當予以替換,並且在安裝時牢記不要將繃簧壓死。
The straw gas generator set uses an aluminum water pump, which sometimes results in poor sealing. The flat surface of the water seal should be polished flat, or the water seal should be flipped 180 ° before installation and use. If the thrust rubber ring is damaged, swollen or deformed, the tension spring lacks elasticity, breaks, etc., it should be replaced, and remember not to press the tension spring tightly during installation.
感謝您的閱讀,此文的文章來源:焦化好色先生在线观看更多的內容和問題請點擊:http://www.dabenche.com好色TV下载安装會繼續努力的為您提供服務,感謝您的支持!
Thank you for reading. The source of this article is: Coking Power Unit. For more information and questions, please click: http://www.dabenche.com We will continue to work hard to provide you with services. Thank you for your support!